Skip to content
Snippets Groups Projects
Commit 77cd9971 authored by Richard Petri's avatar Richard Petri Committed by Peter Maydell
Browse files

hw/timer/armv7m_systick: Update clock source before enabling timer


Starting the SysTick timer and changing the clock source a the same time
will result in an error, if the previous clock period was zero. For exmaple,
on the mps2-tz platforms, no refclk is present. Right after reset, the
configured ptimer period is zero, and trying to enabling it will turn it off
right away. E.g., code running on the platform setting

    SysTick->CTRL  = SysTick_CTRL_CLKSOURCE_Msk | SysTick_CTRL_ENABLE_Msk;

should change the clock source and enable the timer on real hardware, but
resulted in an error in qemu.

Signed-off-by: default avatarRichard Petri <git@rpls.de>
Reviewed-by: default avatarPeter Maydell <peter.maydell@linaro.org>
Message-id: 20220201192650.289584-1-git@rpls.de
Signed-off-by: default avatarPeter Maydell <peter.maydell@linaro.org>
parent c737d868
No related branches found
No related tags found
No related merge requests found
......@@ -149,6 +149,10 @@ static MemTxResult systick_write(void *opaque, hwaddr addr,
s->control &= 0xfffffff8;
s->control |= value & 7;
if ((oldval ^ value) & SYSTICK_CLKSOURCE) {
systick_set_period_from_clock(s);
}
if ((oldval ^ value) & SYSTICK_ENABLE) {
if (value & SYSTICK_ENABLE) {
ptimer_run(s->ptimer, 0);
......@@ -156,10 +160,6 @@ static MemTxResult systick_write(void *opaque, hwaddr addr,
ptimer_stop(s->ptimer);
}
}
if ((oldval ^ value) & SYSTICK_CLKSOURCE) {
systick_set_period_from_clock(s);
}
ptimer_transaction_commit(s->ptimer);
break;
}
......
0% Loading or .